EasyManua.ls Logo

ABB IRB 6620 - Page 73

ABB IRB 6620
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 DressPack and SpotPack
2.4.2 Configuration result for Type Se
3HAC 025861-001 Rev.E 71
Parallel and Can/DeviceNet
The table below shows the available type of wires/media.
Type
At
terminals
in cabinet
At
connection
point. Base,
axis 6
Cable/
part area
Allowed
capacity
Customer Power (CP)
Utility Power
Protective earth
2+2 2+2
1
0,5 mm
2
0,5 mm
2
250 VAC, 5 A rms
250 VAC
Customer signals (CS)
Signals twisted pair
Signals twisted pair and
separate shielded
14
4
14 (7x2)
4 (2x2)
0,23 mm
2
0,23 mm
2
50 V DC, 1 A rms
50 V DC, 1 A rms
Customer bus (CBus)
Bus signals
Bus signals
Signals twisted pair
At bus board
At bus board
6
2
2
6 (3x2)
0,14 mm
2
0,23 mm
2
0,14 mm
2
Can/DeviceNet
spec
50 V DC, 1 A rms
50 V DC, 1 A rms
Servo motor signals
Servo motor power
Protective earth
Signals twisted pair for
resolver
Brake
Temperature control/PTC
At drive
At drive
-
-
-
3
1
6
2
2
1,5 mm
2
1,5 mm
2
0,23 mm
2
0,23 mm
2
0,23 mm
2
600 VAC,
12 A rms
600 VAC
50 V DC, 1 A rms
50 V DC, 1 A rms
50 V DC, 1 A rms
Media
Water/Air (PROC 1-3) 3 12,5 mm
inner
diameter
Max. Air pressure
16 bar/230 PSI.
Max. Water
pressure 10 bar/
145 PSI.
Welding power (WELD)
Lower/Upper arm
Protective earth (Lower/
Upper arm)
2
1
35 mm
2
35 mm
2
600 VAC,
150 A rms at 20°C
(68°F)