Note/IllustrationAction
Screws: Torx pan head screw M4x8 (4 pcs)Secure it with the screws.4
Tightening torque: 1.7 Nm±10%.
xx2100001339
Reconnect:
• Q0 - A1.X1.
• Two ground cables which con-
nects to the left cabinet frame.
5
Concluding procedure
Note/IllustrationAction
Refitting the controller cover on page 121.Refit the top cover.1
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 110.
2
134 Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.3 Replacing the power unit
Continued