Protection classes
Protection class
IP20Controller cabinet, inner compartment for
electronics
IP54FlexPendant
Noise emission
NoteDescriptionData
< 55 dB(A) Leq below +35°CThe sound pressure level one
meter away from each surface
of the controller.
Noise emission
< 60 dB(A) Leq between +35°C
and +45°C
Power supply
ValueMains
220/230 VAC, 1 phaseVoltage for OmniCore E10
100-230 VAC, 1 phase
i
+10%, -15%Voltage tolerance
+10%, -10%
i
50/60 HzFrequency
±3%Frequency tolerance
i
For IRB 1100 controller.
Note
The 2 phases (180-degree phase shift, with grounded neutral), also called
Single-phase three-wire system in North America, can be supported by this
controller.
Load current
There is no integrated fuse inside the OmniCore E10 controller. Add an external
fuse (time-delay) or circuit breaker (class K) according to full load current, as
marked on the controller nameplate. The following table shows the recommended
rating for an external fuse or circuit breaker.
Add an external circuit breaker (class K) according to full load current, as marked
on the controller nameplate. The following table shows the recommended rating
for an external fuse or circuit breaker.
CurrentDescriptionRobot
10 A100-230 VAC, 1 phaseIRB 1100
10 A100-230 VAC, 1 phaseIRB 1200
10 A220/230 VAC, 1 phaseIRB 1300
10 A220/230 VAC, 1 phaseIRB 910INV
10 A220/230 VAC, 1 phaseIRB 920
Continues on next page
38 Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
2 Controller description
2.2 Technical data for OmniCore E10 controller
Continued