ScreenMaster RVG200
Paperless recorder Appendix E Batch recording
OI/RVG200-EN 179
Batch Number Select the required batch numbering system:
Automatic
Off
Text
the batch number increments automatically when a
new batch is started, up to a maximum batch number
of 9,999,999,999.
a batch number is not assigned automatically but may
be entered manually by the operator.
enables the operator to identify the batch with a text
string (maximum 10 characters).
Note. If set to Automatic or Off, this parameter enables the operator to
enter a batch number when starting a batch from the operator menu
see Section E.2.2, page 174.
Field 1 Title
Field 2 Title
Field 3 Title
Enter up to 3 identifying labels for the batch, maximum 20 characters per
field.
Note.
Configured fields are shown on the New Batch dialog box that is
displayed when the operator starts a batch from the operator
menu. This enables the operator to enter further details to identify
the batch both on the recorder and when analyzing the archived
data using DataManager Pro software.
It is important to configure Field 1 because it is used, together with
the batch number, to identify a batch:
on chart annotations
in the alarm event log
during historical review
in the DataManager Pro display / search functions