35
Access codes may also be changed by residents - using the “Code change
activation” function, via the computer program. Refer to “Opening with user’s
code” in Chapter III OPERATION for description of the procedure of code change
by the user.
P2 CHANGING THE ADMINISTRATOR'S ACCESS CODE AND ADDING
PROXIMITY CARDS / KEY FOBS FOR ADMINISTRATORS
Modification of the 6-digit administrator’s access code and adding administrator’s
proximity cards/key fobs to the ACC reader.
Enter the program and wait for “0AKey” and “1M-ACC” to be displayed alternately.
Press 0 to add the administrator’s access code, press 1 to add administrator’s
proximity cards/key fobs.
Upon selecting the option of adding administrator’s code, wait for "CodNr?" to be
displayed, then select any number between 1 and 5 as the order number of the
administrator’s code - the current code will be displayed briefly. Wait for “------”,
then enter six digits of the code in sequence. Upon entering the last digit, the unit
will display "Ready"; the new code is now stored in unit’s memory (previous code
is deleted). Do not enter a code that starts with 1507, as these are the initial digits
of the installer's password (the unit will display "Err! " and will exit the
programming mode).
The E-lock is activated by pressing the "key" button and entering the
administrator’s code, and the second output (F2) is activated by double pressing
the "key" button and entering the administrator’s code. The code may be
abbreviated to the initial four digits, (the option "4 digits of the administrator’s
code" must be enabled in the computer program). The administrator’s code is not
pre-set.
All administrator’s codes are deleted when the factory settings are restored.
Upon selecting the option of adding administrator’s card/key fob, the unit will
display "ACC>>”; now bring administrator’s cards/key fobs close to the reader,
one by one - successful adding of the cards/key fobs will be confirmed by “OK”,
displayed for a brief moment. Cancel adding the cards/key fobs by pressing the
"#" button.
Touching the reader with administrator’s card/key fob will open the door. Pressing
the "key" button before using the card/key fob will activate the second output (F2).
To remove administrator’s cards/key fobs from unit’s memory, use the computer
program. Administrator’s cards are stored in the memory in zone 1, position 0
(address 0).