46
3.- deleting the memory settings of the CDN-230E name tag module
If all entries (names) in the CDN-230E module need to be deleted, turn the power
off, wait approximately 10s and turn it on again by pressing any three module
buttons at the same time. If the reset lock is disabled, the 230E module will
display " SETTINGS RESET ". This operation will delete all the data, will restore
the default intro (main screen with manufacturer's data) and will set the installer’s
password to 0000.
If the reset lock is enabled, no reset is possible. Disable the reset lock must using
the computer program. Note! Installer’s password cannot be restored!!! If the
installer's password needs to be reset with reset lock enabled, the unit should be
shipped to the service centre together with a proof of purchase (ownership) of
the unit or proof of the permit to operate/maintain it.
4.- Deleting all cards in the ACC module
Deleting all cards registered in the module is only possible using the computer
program.
XV. FACTORY SETTINGS
Messages supported in English
Code table with the default number or last entered number
Access codes according to the code table
Installer's password: 0000; As of version K-15: last four digits of the serial
number
No admin codes.
E-lock release time: 4s.
Reversible E-lock disabled
The number of the first supported apartment: 1.
The maximum number of supported apartments: 255
All apartments call enabled
Call volume for all apartments: 1
Ringtone for all apartments: 3
The number of ringing signals for all apartments: 2
Auto opening disabled for all apartments
Additional function (Fd) disabled for all apartments
No additional numbers
No "Call only" receivers
Display of "Call service" message disabled
Further door opening disabled (no further door delay, no further door
opening signals)
Code change by the user disabled
Additional exit - opening (value "0")
Number of openings during conversation: 3
Maximum conversation time: 120s
Factory settings reset enabled
Parameters of the additional I/O module: Port 1 off;
Port 2: control of the built-in OUTPUT - 1s. from "F2" and from the outside unit
(input = 0, output=1, Function No. 2)