P13 PROGRAMMING THE MODULE USING xNP DIRECT CALL BUTTONS
(x - number of buttons)
Programmable function in modules with xNP direct call buttons (x - number of
buttons). Buttons can be assigned to directly call a specific number.
Upon entering this function, the display will show “Local?”; enter the number of
the apartment to which the direct call button is to be assigned, confirm with the
"key" button (the 6-digit apartment is confirmed automatically upon entering the
last digit). The unit will then display "xnP>>" - when it does, press the direct call
button for about 10 seconds. Then the unit will display "Ready"; settings are now
stored in module’s memory. Each of the buttons is programmed individually and
the settings are stored in module’s memory.
Now the value “Local?” is the new call number, to be selected with the keypad
(the physical address of the receiver is calculated by the unit).
P14 OPENING DELAY FROM INPUT
Setting the time between the moment the terminals of the additional INPUT are
shorted and the door is opened. This can be any time in the range 1s to 255s
(default setting: disabled).
Upon entering this function, the display will show current setting and "???? " -
enter a new value from 0 to 255 and confirm with the "key" button. Any one/two-
digit value entered must be confirmed with the "key" button, while a three-digit
value will be saved automatically. The values 1 - 255 are seconds, enter 0 to
disable the delay. The unit will then display “Ready”; now the selected setting is
stored in unit’s memory. Press the "#" button to exit the function without saving
any changes.
P15 TIME TO MESSAGE: "CALL SERVICE”
Setting the time (in months) to the message followed by "Wezwij Serwis” on the
unit (default setting: disabled).
Upon entering this function, the display will briefly show the number of months
("M") and days ("d") to the message (for instance "49M01d) or "Off" if the function
is disabled. When "??" is being displayed, enter the number of months from the
range 1 to 49 (days are automatically reset) and confirm with the "key" button.
Any one-digit value entered must be confirmed with the "key" button, while a two-
digit value will be saved automatically. The longest time that can be set is 49
months. Any higher value will disable this function. "0” will cause immediate
display of the message.