P8 VERIFYING CARD ASSIGNMENT TO APARTMENTS
Verification of the assignment of proximity cards and key fobs to apartments or
to administrator or installer.
Upon selecting the function, the unit will display "====“; when a card or key fob
is brought closer to the ACC reader, the unit will display the number of the
apartment to which the card (key fob) is assigned. Use the "#" button to turn the
function off. If a triple beep can be heard upon touching the reader with the
card/key fob and no message is displayed, the card/key fob is not registered in
the ACC reader. If the unit displays “Admin”, the card/key fob is used by the
administrator, if it displays "Instal" - it is used by the installer.
P9 ENTERING NEW ACCESS CODE TABLE
Entering the four-digit number of the code table, used to generate 255 individual
access codes for residents. In systems with multiple units (Master / Slave), by
entering the same number of the code table in each unit, the same codes are set
across the whole system. In case of INSPIRO+ series, the code table works only
for zone 1, code tables for the remaining zones needs to be entered using the
computer program.
Upon selecting the function, the unit will display the current code table. When it
will display “----”; now the new table number can be entered. Use the "#" button
to exit the function without changing the setting. Upon entering the last fourth digit
of the table, the unit will generate 255 codes (confirming with a beep sound).
Then the unit will display "Ready"; all codes and the code table number are now
stored in unit’s memory.
The code table for Master panels is a 4-digit number, which can be found on the
back of the unit. The code table for Slave panels must be the same as the for
Master panels. Order numbers in the code table (1 to 255) always correspond to
the physical addresses in the uniphones (irrespective of shifts and other settings).
If the code table number 9999 is entered, using the access codes is disabled
P10 E-LOCK
Activation of reversible E-lock - switching on constant voltage at the "ELOCK"
output, which ceases during door opening.
Upon selecting the function, the unit will display the current setting: "On" if
reversing E-lock is activated, "Off" if it is not. When "???" is being displayed, the
setting can be changed. Press "1" to enable the reversing E-lock (the unit will
display "On" briefly), press "0" to disable it (the unit will display “Off" briefly). Use
the "#" button to exit the function without changing the setting.
Then the unit will display "Ready"; settings are now stored in unit’s memory.