ADTECH9 Series CNC Maintenance Manual
- 118 -
Output signal stops keeping for the seconds specified by P1.023
(reverse phase).
Output signal follows the hertz specified by P1.024 in working state,
and used for oil supply devices. If it is set to 0, the system will keep low
output level.
025 Back Home Mode Configuration (BIT)
Range :
Unit :
Authority : Operation admin or higher
Default : Z – XYABC
Effective time : Instant
Note : Set the zero sequence of each axis; up to three sections can be set.
026 Arc speed for Radii
027 Arc speed for Speed
Range :
Unit : Coefficient
Authority : Operation admin or higher
Default : 50, 100
Effective time : Instant
Note : Used to restrict the arc processing speed automatically. This parameter is
valid in pretreatment mode.
The bigger the radius coefficient is, the lower the arc speed is.
The bigger the acceleration coefficient is, the higher the arc speed is.
028 Pretreatment Code Setting
Range : 100~5000
Unit : Instruction line
Authority : Operation admin or higher
Default : 500
Effective time : Instant
Note : Set the pre-reading instruction lines; if the pretreatment processing