EasyManuals Logo

Adtech CNC9640 User Manual

Default Icon
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
ADTECH9 Series CNC Maintenance Manual
- 117 -
Range : 0~1
Unit : None
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : Control mode corresponding to spindle S code (frequency conversion
mode)
0 : Analog output
1: Section speed regulation (4-digit code determined by output port
configured by spindle parameters P6.014 ~ P4.017), as below:
P6.014------S0
P4.015------S1
P4.016------S2
P4.017------S3
In analog output mode, the analog voltage is:
VS/MaxRPM
S is the rotation set by the user, and MaxRPM is the maximum rotation
of spindle set by the parameter (P4.017);
In switching quantity mode, constitute block 0-15 according to
four-digit code to output; S code value is restricted to 0-15;
022 Lubricant Pressure Open(min)
023 Lubricant Pressure Keep(sec)
024 Lubricant Pressure Out Freq(Hz)
Range :
Unit :
Authority : Operation admin or higher
Default : 0
Effective time
Note
:
:
Instant
Set the schedule start and holding time of the automatic oil pump of the
system
Schedule open setting is that the settings of P6.045 oil pump output
ports when the timing reaches specified value after the system starts and
times.

Table of Contents

Other manuals for Adtech CNC9640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9640 and is the answer not in the manual?

Adtech CNC9640 Specifications

General IconGeneral
BrandAdtech
ModelCNC9640
CategoryControl Systems
LanguageEnglish

Related product manuals