Programmer’s Guide 10-33
Menu Map with SCPI Commands
Menu Map for 8712ET/ES and 8714ET/ES
Table 10-12 DISPLAY Functions, 8712ET/ES and 8714ET/ES (3 of 5)
1. The active measurement channel configuration determines the order of appearance
and the content of the softkey menus.
2. For fault location measurements.
3. After Edit Limit (Min/Max) is pressed, the up key can be used to increase the limit
(CALC[1|2]:LIM:MARK:STAT:MEAN:MAX UP) and the down key can be used to
decrease the limit (CALC[1|2]:LIM:MARK:STAT:MEAN:MAX DOWN).
KEYSTROKES SCPI COMMAND
DISPLAY
1
, Limit Menu, (continued)
Delete Limit (continued)
Edit Limit
2
(menu selection only)
Begin Frequency
(Begin Distance)
2
CALC[1|2]:LIM:SEGM[n]:FREQ:STAR <num> HZ
End Frequency
(End Distance)
2
CALC[1|2]:LIM:SEGM[n]:FREQ:STOP <num> HZ
Begin Limit CALC[1|2]:LIM:SEGM[n]:AMPL:STAR <num>
End Limit CALC[1|2]:LIM:SEGM[n]:AMPL:STOP <num>
Limit Options
CALC[1|2]:LIM:SEGM[n]:TYPE PMAX;STAT ON
2
Limit Line ON off CALC[1|2]:LIM:DISP [ON|OFF]
Limit Text ON off DISP:ANN:LIM:ICON2:TEXT [ON|OFF]
Limit Icon ON off DISP:ANN:LIM:ICON2:FLAG [ON|OFF]
Limit Icon X Position DISP:ANN:LIM:ICON1:POS:X <value>
Limit Icon Y Position DISP:ANN:LIM:ICON1:POS:Y <value>
Mkr Limits (menu selection only)
Edit Limit (Min/Max)
3
(menu selection only)
Max Limit CALC[1|2]:LIM:MARK:STAT:MEAN:MAX <value>
Min Limit CALC[1|2]:LIM:MARK:STAT:MEAN:MIN <value>
Mkr Limit on OFF CALC[1|2]:LIM:MARK:STAT:MEAN [ON|OFF]
Limit Test ON off CALC[1|2]:LIM:STAT [ON|OFF]