11-8 Programmer’s Guide
SCPI Command Summary
SCPI Device Command Summary
Table 11-2 CALCulate (4 of 7)
1. Binary parameters accept the values of 1 (on) and 0 (off) in addition to ON and OFF.
2. Numeric parameters may include an appropriate suffix; if no suffix is included, the
default (HZ for frequency or S for time) is assumed.
SUBSYSTEM COMMANDS FORM DESCRIPTION
CALCulate[1|2]:LIMit:SEGMent
[1|2|12]:FREQuency:STOP
<num>
2
NR3 Sets the End Frequency for the
specified limit segment.
CALCulate[1|2]:LIMit:SEGMent
[1|2|12]:POWer:STARt
<num>
2
NR3 Sets the Begin Power for the specified
limit segment.
CALCulate[1|2]:LIMit:SEGMent
[1|2|12]:POWer:STOP
<num>
2
NR3 Sets the End Power for the specified
limit segment.
CALCulate[1|2]:LIMit:SEGMent
[1|2|12]:STATe
<ON|OFF>
1
NR1 Turns the specified limit segment on/off
— adds or deletes the segment.
CALCulate[1|2]:LIMit:SEGMent
[1|2|12]:TYPE
<char>
CHAR Sets the limit type for the specified
segment, choose from
LMAX|LMIN|PMAX|PMIN (Max Line,
Min Line, Max Point, Min Point) — sets
all of the segment's limit parameters to
their default values.
CALCulate[1|2]:LIMit:STATe
<ON|OFF>
1
NR1 Turns the limit test on/off.
CALCulate[1|2]:MARKer:AOFF command
only
Turns off all markers for a given
channel — this has the effect of turning
off marker functions and tracking as
well.
CALCulate[1|2]:MARKer:BWIDth
<num>
2
NR3 Calculates the bandwidth of a
bandpass filter — num is the target
bandwidth
(−3 for the 3 dB bandwidth).