Programmer’s Guide 11-59
SCPI Command Summary
SCPI Device Command Summary
Table 11-22 SYSTem (1 of 8)
1. <freq>, <dur>, and <vol> are optional <num> parameters.
2.Binary parameters accept the values of 1 (on) and 0 (off) inaddition to ON and
OFF.
3. For use with IBASIC—this command cannot be executed from an external
controller.
4. A delay of 5 seconds is required before a command is sent to the new address.
SUBSYSTEM COMMANDS FORM
DESCRIPTION
SYSTem:BEEPer[:IMMediate]
[<freq>[,<dur>[,<vol>]
1
NR3, NR3,
NR3
Instructs the analyzer to beep.
Arguments are frequency (Hz),
duration (seconds), and volume
(0 to 1).
SYSTem:BEEPer:VOLume <num> NR2 Sets the volume of the beeper
— num is a number between 0
for 0% and 1 for 100%.
SYSTem:COMMunicate:GPIB
:CONTroller[:STATe]<ON|OFF>
2,3
NR1 Makes the analyzer the system
controller.
SYSTem:COMMunicate:GPIB:ECHO
<ON|OFF>
2
NR1 Turns GPIB mnemonic echo
on/off .
SYSTem:COMMunicate:GPIB:HCOPy
:ADDRess <num>
NR1 Sets the address of an GPIB
printer or plotter for hardcopy
output — num must be an
integer between 0 and 30.
SYSTem:COMMunicate:GPIB[:SELF]
:ADDRess <num>
4
NR1 Sets the analyzer's GPIB
address — num must be an
integer between 0 and 30.
SYSTem:COMMunicate:LAN:BOOTp
:HOST <string>
STRING Sets the host name or host IP
address of the remote host that
receives the BOOTP requests.
SYSTem:COMMunicate:LAN:BOOTp
:STATE <OFF|0|ON|1>
NR1 Sets a BOOTP request when
the analyzer boots up.