EasyManuals Logo
Home>Agilent Technologies>Inverter>Agilent 33500 Series

Agilent Technologies Agilent 33500 Series User Manual

Agilent Technologies Agilent 33500 Series
429 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
LXI Subsystem
LXI:MDNS:SNAMe:DESired <name>
LXI:MDNS:SNAMe:DESired?
Sets the desired mDNS service name.
Parameter Typical Return
Quoted string of up to 63 characters, default is
Agilent <Model_Name> Arbitrary Waveform
Generator - <Serial_Number>".
"Agilent 335xxx Arbitrary Waveform Generator - 99999", where
xxx is the last three characters of the model number, and 99999
is the last five digits of the serial number.
Set the mDNSservice name to "Waveform Generator":
LXI:MDNS:SNAM:DES "Waveform Generator"
l This setting is non-volatile; it will not be changed by power cycling or *RST.
l Setting is set to default value after SYSTem:SECurity:IMMediate.
LXI:MDNS:SNAMe[:RESolved]?
Returns the resolved (unique) mDNS service name in the form <Desired mDNS Service Name>(N). The N is an
integer appended if necessary to make the name unique. The desired name may be truncated, if necessary, to make
room for the appended integer.
Parameter Typical Return
(none) "Agilent 335xxx Arbitrary Waveform Generator - 00309", where xxx is the last three characters of
the model number, and 00309 is the last five digits of the serial number.
Return resolved mDNS service name:
LXI:MDNS:SNAMe:RESolved?
l The resolved mDNS service name will be the desired service name (LXI:MDNS:SNAMe:DESired), possibly with
"(N)" appended, where N is an integer, only if if is necessary to make the name unique.
LXI:RESet
Resets LAN settings to a known operating state, beginning with DHCP. If DHCP fails, it uses AutoIP. It also clears the
WebUI password, if set.
Parameter Typical Return
(none) (none)
Reset the LANsettings:
LXI:RES
l Depending on your network, the LAN interface may take several seconds to restart after this command is sent.
l If the LAN interface or specific LAN services (VXI-11, sockets, and so on) have been disabled by SYS-
Tem:COMMunicate:ENABle, you must separately re-enable the interface or services and cycle power on the instru-
ment for the LAN to be operational.
242 Agilent 33500 Series Operating and Service Guide

Table of Contents

Questions and Answers: