Assembly Replacement
A6 Frac-N
2-22
A6 Frac-N
Tools Required
• none
Removal Procedure
Refer to Figure 2-10 for this procedure.
1. Disconnect the power cord.
2. Remove the covers from the signal generator. Refer to "Outer Instrument Cover" on page 2-4 and
"Inner Instrument Cover" on page 2-6.
3. Position the signal generator with the front panel facing you.
4. Lift the retention levers and disconnect the A6 Frac-N from the A31 Motherboard.
5. Lift the A6 Frac-N out of the slot.
Replacement Procedure
• Reverse the order of the removal procedure.
• Perform the post-repair adjustments and performance tests that pertain to this removal procedure.