124
Settings and Adjustments
Configure on the device.
4
Monitor
Configure settings related to monitoring and scan monitoring.
Scan monitoring: This function automatically switches monitoring between multiple stations and network cameras
(other than VoIP phones) for a certain interval.
1. Tap [Monitor] on the Settings (1/2) screen.
The Monitor Settings screen is displayed.
2. Change the settings.
3. Tap [Back].
The settings are saved.
Entry Description Settings Default values
MONITOR TIMER Configure the time until monitoring
automatically stops, when a station or
network camera is monitored individually.
Scan monitoring will not end until an end
operation is performed on the station.
10 - 600 seconds:
Configure between 10 and
600 sec (by 1 sec).
∞ (infinite): Do not end until
end operation is performed.
60 sec
SCAN MONITOR
DWELL TIME
Configure the switchover interval time for
scan monitoring.
5 sec
10 sec
30 sec
5 sec
Scan Monitor Settings Configure the stations and network cameras
for which to perform scan monitoring.
Refer to
“How to configure scan monitoring
(→page 125)” for information on how to
configure this.
--

Table of Contents