Page 39
Chapter 3: Recording Sequences
Selecting a Tempo Source
This allows the performance of each sequence to a set tempo or the master tempo set by MPC
2000XL.
.......................................................
..................................................................................................
Sq:01-(Sequence01)
TrMUTE SOLO Tr +
Now:001.01.00
STEP EDIT Tr -
™:120.0(MAS) Timing:1/16 Tsig: 4/ 4Tsig: 4/ 4
Count:OFF Loop: ONLoop: ON Bars: 0Bars: 0
Tr:01-Track01 ON:YES Pgm:OFF
S:DRUM1:OFF New Pgm-A S:DRUM1:OFF New Pgm-A Velo%:100
Move the cursor to the Tempo Source Field as shown above and set the tempo source with the
DATA wheel.
(SEQ)
Each sequence that you play back may have a different tempo. When (SEQ) is selected,
the sequence’s tempo is displayed in the Tempo field. It is possible to set this tempo for
each sequence individually. When playing sequences, this is useful if you want each se-
quence to play at its preset tempo. The sequence’s tempo is saved to disk along with se-
quence data when a sequence is saved.
(MAS)
The master tempo is a single tempo setting that applies to all sequences and songs. When
playing sequences this is useful if you always want each selected sequence to play at the
same tempo. This can be especially useful in the “Next sequence” mode, where following
sequences may have different tempos and you want them to all play at the same tempo.
This tempo setting is not saved in the sequence file.

Table of Contents

Other manuals for Akai MPC 2000XL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Akai MPC 2000XL and is the answer not in the manual?

Akai MPC 2000XL Specifications

General IconGeneral
Polyphony32 voices
Sampling Frequency44.1 kHz
Sampling Resolution16-bit
Sample Memory2MB standard, expandable to 32MB
Pads16 velocity-sensitive pads
Sequencer Resolution96 PPQN
Outputs8 individual outputs, stereo master output
FilterDigital resonant filter
Display240 x 64 pixel LCD
TypeSampler/Sequencer
Storage3.5" floppy disk
EffectsOptional effects board
Power SupplyAC 100-240V, 50/60 Hz
Maximum Sampling Time22.8 minutes (with 32 MB RAM)