System Information Commands
Page 308 7210 SAS D, E, K OS Basic System Configuration
Guide
connected through OMC interface shelf-id can be 1-7 and if connected through USB interface
shelf-id should be 0.
• If the main shelf has any other shelf-id (that is 1-7), the shelf will not become operational.
create — Keyword used to create the vwm-shelf-id.
card
Syntax card card-id
Context config>system>vwm-shelf
Description Platforms Supported: 7210 SAS-E.
This command provides the context to provision the information for the modules that can be plugged
into the slots on the 1830 VWM clip-on device.
This command provides the user for a better control over the modules plugged into the 1830 CWDM
device slots. User can pre-provision acceptable modules by configuring the card-type parameter with
the appropriate vwm-acronym. Modules are identified using the card type acronyms listed below.
The no form of the command removes the configured card ID and the software forgets all the
information it has for the card. Software will not raise any events/traps/alarms for the card and clear
all pending events/traps/alarms/LEDs.
Default No default
Parameters card-id — The card ID used to identify the card on the 1830 VWM clip-on device attached to 7210
SAS. Card ID 1 identifies the module in slot #1 of the 1830 CWDM device and Card ID 2 identifies
the module in slot #2 of the 1830 CWDM device.
Values [1 | 2]
shutdown
Syntax [no] shutdown
Context config> system> vwm-shelf <vwm-shelf-id>
Description Platforms Supported: 7210 SAS-E.
This CLI command allows the user to administratively disable the management of the clip-on device
identified by the parameter vwm-shelf-id. When this command is executed, 7210 software will clear
all pending events/traps/alarms related to this shelf.
The no form of the command allows the user to administratively enable the management of the clip-
on device. The software raises appropriate events/traps/alarms for the device.
Default no shutdown