System Management
7210 SAS D, E, K OS Basic System Configuration Guide Page 319
less than or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Values rising, falling, either
Default either
cflash-cap-alarm
Syntax cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context config>system>thresholds
Description This command enables capacity monitoring of the compact flash specified in this command. The
severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
Values cf1:|cf2:|uf1: , cf1-A:
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated ’startup-alarm’ is equal to ’rising’ or ’either’.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the ’falling-
threshold’ value.
Default 0
Values -2147483648 — 2147483647
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold value.
Default 0
Values -2147483648 — 2147483647
interval seconds — Specifies the polling period, in seconds, over which the data is sampled and
compared with the rising and falling thresholds.
Values 1 — 2147483647