System Alarm Commands
Page 320 7210 SAS D, E, K OS Basic System Configuration
Guide
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
Values log — An entry is made in the RMON-MIB log table for each event occurrence.
This does not create a TiMOS logger entry. The RMON-MIB log table entries can
be viewed using the show>system>thresholds CLI command.
trap — A TiMOS logger event is generated. The TiMOS logger utility then
distributes the notification of this event to its configured log destinations which
may be CONSOLE, telnet session , memory log, cflash file, syslog, or SNMP trap
destinations logs.
both — Both a entry in the RMON-MIB logTable and a TiMOS logger event are
generated.
none — No action is taken.
Default both
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is equal
to rising or either, then a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is equal to
falling or either, a single falling threshold crossing event is generated.
Default either
Values rising, falling, either
Configuration example:
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900 interval 120
rmon-event-type both start-alarm rising.
cflash-cap-warn
Syntax cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context config>system>thresholds
Description This command enables capacity monitoring of the compact flash specified in this command. The
severity level is warning. Both a rising and falling threshold can be specified. The no form of this
command removes the configured compact flash threshold warning.
Parameters cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
Values cf1:|cf2:|uf1:, cf1-A:
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS-D and is the answer not in the manual?

Alcatel-Lucent 7210 SAS-D Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS-D
CategorySwitch
LanguageEnglish

Related product manuals