Parameters ip-filter ip-filter-idSpecifies an IP filter for this tod-suite.
Values 1 — 65535
ipv6-filter ip-filter-idSpecifies an IPv6 filter for this tod-suite.
Values 1 — 65535
time-range time-range-nameName for the specified time-range. If the time-range is not
populated the system will assume the assignment to mean “all times”. Only one entry without a
time-range is allowed for every type of policy. The system does not allow the user to specify
more than one policy with the same time-range and priority.
Values Up to 32 characters
priority priorityPriority of the time-range. Only one time-range assignment of the same type and
priority is allowed.
Values 1 — 10
mac mac-filter-idSpecifies a MAC filter for this tod-suite.
Values 1 — 65535
qos
Syntax qos policy-id [time-range time-range-name] [priority priority]
no qos policy-id [time-range time-range-name] [
Context config>cron>tod-suite>ingress
Description This command creates time-range based associations of previously created QoS policies. Multiple
policies may be included and each must be assigned a different priority; in case time-ranges overlap,
the priority will be used to determine the prevailing policy. Only a single reference to a policy may be
included without a time-range.
The no form of the command reverts to the
Parameters policy-id — Specifies an egress QoS policy for this tod-suite.
Values 1 — 65535
time-range time-range-nameName for the specified time-range. If the time-range is not
populated the system will assume the assignment to mean “all times”. Only one entry without a
time-range is allowed for every type of policy. The system does not allow the user to specify
more than one policy with the same time-range and priority.
Values Up to 32 characters
Default "NO-TIME-RANGE" policy
priority priorityPriority of the time-range. Only one time-range assignment of the same type and
priority is allowed.
Values 1 — 10
Default 5

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS-D and is the answer not in the manual?

Alcatel-Lucent 7210 SAS-D Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS-D
CategorySwitch
LanguageEnglish

Related product manuals