System Alarm Contact Commands
Page 376 7210 SAS D, E, K OS Basic System Configuration
Guide
shutdown
Syntax [no] shutdown
Context config>system>alarm-contact-input
Description This command stops tracking the state changes associated with the alarm contact input .The system
does not generate or clear the alarms for the alarm-contact input, but if an alarm is generated for the
alarm-contact-input, the system clears the alarm when the shutdown command is executed.
The no form of the command starts tracking the state changes associated with the alarm contact input.
Default Shutdown
trigger-alarm-msg
Syntax [no] trigger-alarm-msg {alarm-msg-text}
Context config>system>alarm-contact-input alarm-contact-input-id
Description This command allows the user to configure a text message for use along with SNMP trap and Log
message that are sent when the system generates an alarm. The system generates a default message if
the message is not configured. The system does not generate a trap or log if no form of the command
is enabled.
Default None
Parameters alarm-msg-text — A printable character string, up to 160 characters in length.
Values [80 chars max]