7705 SAR-M Ports
166 7705 SAR-M Chassis Installation Guide
Alarm Examples
Table 37 lists critical, major, minor, and warning alarm examples.
Ethernet Ports
There are three RJ-45 and four optical (SFP) connectors on the front of the 7705 SAR-M that
provide Ethernet access to seven Ethernet ports.
Use CAT5E (Gigabit Ethernet) shielded cables to attach customer equipment to the
7705 SAR-M RJ-45 Ethernet ports. Shielded cable must be used to maintain EMC
compliance.
Figure 42 shows the pin numbering.
Figure 42: Ethernet Port RJ-45 Connector Pin Numbers
Table 37: Alarm Examples
Alarm Severity Examples
Critical • two or more fans have failed
• a power feed has failed
• a critical external alarm has been detected
Major • an over-temperature condition has been detected
• a major external alarm has been detected
Minor • one fan has failed
• a minor external alarm has been detected
Warning • interface becomes operational/non-operational
Pin 8Pin 1