7705 SAR-8 Overview
Page 48 7705 SAR-8 Installation Guide
Figure 7 shows a sample 7705 SAR-8 adapter card.
Filler Plates
Figure 8 shows a filler plate. Filler plates (blank panels) are required on all empty slots to
prevent dust accumulation, help control airflow, help confine electromagnetic interference,
and for safety reasons. Filler plates do not have board components or connector pins.
Figure 4 shows a filler plate on slot MDA 3.
Power System
The 7705 SAR-8 has two power connectors mounted on the front of the chassis. These
connectors provide access for two independent ā48/ā60 VDC power feeds, providing power
redundancy for the system. When only one power feed is used, the system does not have
power supply redundancy. The 7705 SAR-8 has a distributed power design, where each
CSM and adapter card provides independent power for its own functionality. The power
system has no field-replaceable parts.
Figure 7: 7705 SAR-8 Adapter Card
A16-CHDS1
Stat
Pwr
Act
Ports 1-16
Port
19637
Figure 8: 7705 SAR-8 Filler Plate
19638