T1/E1 Cables
Table 4 describes the T1/E1 cables that are available for the 7705 SAR-8, and gives the
name used in the various installation guides as well as the name used in the orderable parts
catalog. These cables are used to make the connection between the equipment (7705 SAR-8)
and the distribution panel.
Note:
1. The T1/E1 cables with 68-pin Amp connectors at both ends have their connectors attached such that when
connected to a card or distribution panel, the cable can run to the left or the right side depending on which
connector is used.
For pinout information on the cables listed above, refer to the 7705 SAR 16-port T1/E1
ASAP Adapter Card Installation Guide. For information about wire identification by color,
see Wire Identification by Color on page 113.
Serial Data Interface Card Cables
The 12-port Serial Data Interface card can be connected to a V.35 distribution panel using a
2 m (6.5 ft) V.35 cable or to an RS-232 distribution panel using a 2 m (6.5 ft) RS-232 cable.
It can also be connected to a customer-supplied distribution panel using a 10 m (32.8 ft)
single-ended cable; the unterminated end connects to the distribution panel. The cable
assemblies consist of two cables bundled into a single assembly.
The cable assemblies have a 68-Pos plug that attaches to the 68-pin mini-Champ connectors
on the 12-port Serial Data Interface card faceplate and a 50-pin Champ connector that
attaches to the rear of the V.35 or RS-232 distribution panel.
Table 4: T1/E1 Cables
Name used in Installation Guide Name used in Orderable Parts Catalog
68-pin AMP connector to open-ended
T1/E1 cable
T1/E1 Cable 28 AWG Open-ended 30m
T1/E1 Cable 28 AWG Open-ended 15m
T1/E1 Cable 26 AWG Open-ended 30m
T1/E1 Cable 26 AWG Open-ended 15m
68-pin AMP to 68-pin AMP T1/E1 cable
(1)
T1/E1 Cable for Distribution Panel, 1m
Note: The Serial Data Interface card cables use small diameter 30 AWG copper. Use of the
open-ended cable for punch-block applications is not recommended due to the potential for
wire breakage. Other connection methods, such as screw type panels, should be used.