System Synchronization Commands
The following commands apply to the 7750 SR-7, and 7750 SR-12 models.
config
—system
sync-if-timing
abort
begin
bits
interface-type {ds1 [{esf | sf}] | e1 [{pcm30crc | pcm31crc}]}
—no interface-type
[no] shutdown
commit
ref-order first second [third]
—no ref-order
ref1
[no] shutdown
source-port port-id
—no source-port
ref2
[no] shutdown
source-port port-id
—no source-port
[no]
The following commands apply to the 7750 SR-c12 models.
config
—system
sync-if-timing
abort
begin
commit
ref-order first second [third]
—no ref-order
ref1
bits-interface-type {ds1 [{esf | sf}] | e1 [{pcm30crc | pcm31crc}]}
—no bits-interface-type
[no] shutdown
source-bits slot/mda
—no source-bits
source-port port-id
—no source-port
ref2
bits-interface-type {ds1 [{esf | sf}] | e1 [{pcm30crc | pcm31crc}]}
—no bits-interface-type
[no] shutdown
source-bits slot/mda
—no source-bits
source-port port-id
—no source-port
[no]