-50% ~ +99% ±1%, Max Resolution: 0.1 %
Relative Accuracy “Phase to Phase” ± 0.1%
Dissipation Factor - DF (frame – stator)
1 – 100% measurement range (expressed as a percentage)
1 – 10% ±0.75% (C = 10 – 1000 nF) ±1.0% (all other values of C within range 2-2000 nF)
(This specification is based on battery operation and USB not connected to PC)
Capacitance (frame – stator)
2 – 2,000 nF measurement range
(This specification is based on battery operation and USB not connected to PC)
0 – 5000 MΩ @500V or 1000V
1 – 999 MΩ ±3%, all other values ±5%
3 x Motor input/output - push-pull connectors 4-pole
High Voltage output - Ø 4mm safety jack
PC communication: USB type B connector
Charger input - 2.5mm diameter center pin DC-jack
Sealed tactile switches with backlight overlay
Graphic LCD, monochrome 128 x 128 pixels (3.8”), white LED backlight.
Temperature Range (Storage)
-20 °C to +55 °C (-4 °F to +131 °F)
Temperature Range (Operating)
-10 °C to +50 °C (-4 °F to +122 °F)
0-80% relative humidity, non-condensing