will add counts to the total number of Start Pulses counter. Refer
to Collecting Audit Information.
To exit the Start Pulse Test, press the DELICATES 30 (<) key-
pad. The control will return to the Testing Mode.
Door Switch Input Test d 15
This test will display whether the washer door is open or closed.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. If the door is closed,
the display will show dr CL. If the door is open, the display will
show dr oP.
To exit the test, press the DELICATES 30 (<) keypad. The con-
trol will return to the Testing Mode.
Door Lock Input Test d 16
This test will display whether the door is locked or unlocked.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, close the door and press the START (enter) keypad. The
control will lock the door. If the door is open, the display will
show CLoSE and door. The door must be closed to enter test.
If the door is unlocked, the display will show dr UL. After the
door is locked, the display shows dr Lo and 5 seconds later the
door will unlock. This sequence is repeated every time the
START (enter) keypad is pressed.
To exit the test, press the DELICATES 30 (<) keypad. The con-
trol will return to the Testing Mode.
Show Fill Time Test d 17
This test will display the average fill time. This average will be
calculated by taking the average of the last 10 fill times.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
FL XXX. The XXX will be the average fill time in seconds.
To exit the Show Fill Time Test, press the DELICATES 30 (<)
keypad. The control will return to the Testing Mode.
Show Drain Time Test d 18
This test will display the average drain time. This average will be
calculated by taking the average of the last 10 drain times.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
dr XXX. The XXX will be the average fill time in seconds.
To exit the Show Drain Time Test, press the DELICATES 30 (<)
keypad. The control will return to the Testing Mode.
Temperature Sensor Display Test d 19
This test displays the temperature sensed at the thermistor. To
start test, control must be in the Testing Mode. Refer to How to
Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
XXXF or XXXC where XXX is the temperature displayed in either
Fahrenheit or Celcius.
If the control senses a shorted thermistor, SHort will be dis-
played. If the control senses an open thermistor, oPEn will be
displayed.
To exit the Temperature Sensor Display Test, press the DELI-
CATES 30 (<) keypad. The control will return to the Testing
Mode.
Out of Balance Switch Test d 22
This test displays whether the out of balance switch is open or
closed. To start test, control must be in the Testing Mode. Refer
to How to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
bA oP if the switch is open or bA CL if the switch is closed.
To exit the Out of Balance Switch Test, press the DELICATES 30
(<) keypad. The control will return to the Testing Mode.
External Outputs Test d 23
This test will allow any one of the external outputs to be selected.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
ES X where X is the output number. Press the NORMAL 40 (∧)
or the DELICATES COLD (∨) keypad to scroll through the out-
puts.
Press the START (enter) keypad to energize the selected external
output. ES Xon will be displayed. Press the START (enter) again
or the DELICATES 30 (<) keypad to turn off the selected exter-
nal output.
To exit the External Outputs Test, press the DELICATES 30 (<)
keypad. The control will return to the Testing Mode.
Water Purge Test d 24
This test allows the user to test water removal from the machine.
To start test, control must be in the Testing Mode. Refer to How
to Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
PUrgE and the START (enter) keypad LED will flash. Begin the
test by pressing START (enter). If the door is open, CLoSE,
Testing Machine and Electronic Control Functions
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
101 Part No. 805405ENR5