1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until IrA
En appears in the display.
4.
When IrA En appears in the display, press the START (en-
ter) keypad. The current IR Access status will appear in the
display.
on = Option Enabled (factory default setting)
oFF = Option Disabled
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Manual Rapid Advance rAPdEn
This option allows the owner to enable or disable the rapid ad-
vance feature. Refer to Rapid Advance Feature section for more
information.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until
rAPdEn appears in the display.
4.
When rAPdEn appears in the display, press the START (en-
ter) keypad. The current Manual Rapid Advance status will
appear in the display.
on = Option Enabled (factory default setting)
oFF = Option Disabled
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Manual Diagnostics diAgEn
This option allows the owner to enable or disable the manual di-
agnostics option. Refer to Testing Machine and Electronic Con-
trol Functions section for more information.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until
diAgEn appears in the display.
4.
When diAgEn appears in the display, press the START (en-
ter) keypad. The current Manual Diagnostics status will ap-
pear in the display.
on = Option Enabled (factory default setting)
oFF = Option Disabled
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Factory Test Ft En
This option allows the owner to enable or disable access to Facto-
ry Test.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until Ft
En appears in the display.
4.
When Ft En appears in the display, press the START (enter)
keypad. The current Factory Test status will appear in the dis-
play.
on = Option Enabled (factory default setting)
oFF = Option Disabled
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Lucky Cycle LUC-
This option allows the owner to program the machine to provide
a free or reduced vend cycle to users after a certain number of
machine cycles have occurred.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
Programming Control
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
90 Part No. 805405ENR5