Entering the Manual Mode
How to Enter the Manual Mode
For programming, testing, and retrieving information from the
control, it is often necessary to enter the Manual Mode by follow-
ing the four simple steps below. For an overview of entering the
Manual Mode, refer to the flowchart on the following page.
1. If accessing Diagnostic Tests that take control of machine op-
eration, be sure the washer is in the Start or Ready Mode be-
fore continuing to step 2. If the washer is in an active cycle,
rapid advance through the cycle. Refer to Rapid Advance
Feature.
2. Open the service door.
NOTE: The coin vault switch must be closed to en-
ter Manual Mode.
3. While pressing and holding the A keypad with one hand,
press the NORMAL 90 keypad with the other hand.
4.
The display will show rAPid .
5. Press the NORMAL 40 () or the DELICATES COLD ()
keypad to scroll through the options until the desired option
appears in the display.
6. Press the START (enter) keypad.
NOTE: After entering Manual Mode, if no keypads
are pressed for 4.25 minutes, the control will return
to the previous mode of operation.
7. To exit, press the DELICATES 30 ( < ) keypad. The control
will revert back to Ready Mode.
Manual Mode Navigation
Manual Mode is broken into five groups: Manual Programming,
Manual Read Audit, Manual Reset, Manual Rapid Advance and
Manual Diagnostics. Manual Programming can only be turned on
or off with an external device or the network. Refer to the appro-
priate instruction manual. Manual Rapid Advance and Manual
Diagnostics can be turned on and off using an external device, by
manual programming, or with the network.
By default, all groups are turned on.
The manual features available in each group are as follows (the
menu shown on the display in this mode is in parentheses).
Manual Programming (Prog)
Manual Read Audit (AUdit)
Manual Reset (rESEt)
Rapid Advance (rAPid)
Manual Diagnostic Tests (diAg)
If a group is turned off, the display will change from the selected
feature to oFF when the START (enter) pad is pressed. An audio
signal will then sound for one (1) second and the display will re-
turn to the selected feature. The features in the group cannot be
entered.