Option Number Option Display Description Factory Default Value Range
p
ovrFLd
Overflow Mode Dis-
play
on on/oFF
q
CLrErr
Allow Error Clearing oFF on/oFF
20
tP F C
Temperature (F/C)
(Heater/Temp Sensor
only)
FAHrEn FAHrEn/CELCiU
21
FL Hot
Hot Water Temperature
(Heater/Temp Sensor
only)
140F/60C 35F-194F/2C-90C
22
FL HC
Warm Water Tempera-
ture (Heater/Temp Sen-
sor only)
104F/40C 35F-194F/2C-90C
23
FL CLd
Cold Water Tempera-
ture (Heater/Temp Sen-
sor only)
35F/2C 35F-194F/2C-90C
24
CooLdn
Cool Down Tempera-
ture (Heater/Temp Sen-
sor only)
140F/60C 50F-160F/10C-71C
25
FL Lo
Low Water Level 6 1 - 30
26
FL NEd
Medium Water Level 10 1 - 30
27
FL Hi
High Water Level 15 1 - 30
28
FLSH t
Flush Out Time for Fill
Steps
25 0 - 255
29
norF t
No Refill After Time
for Agitate Steps
255 0 - 255
30
rtC-
Real Time Clock Menu
a
rtC 1
Set Real Time Clock
Minutes
0 - 59
b
rtC 2
Set Real Time Clock
Hours
0 - 23
c
rtC 3
Set Real Time Clock
Day of Week
1 - 7
d
rtC 4
Set Real Time Clock
Date of Month
1 - 31
e
rtC 5
Set Real Time Clock
Month
1 - 12
Table continues...