4 Enter the SHOW RUNNING-CONFIG command to display the running configuration of
the master switch. You should use the display to confirm that you designated the
correct 5Gbps trunk ports for the master and member switches. The display should
contain INTERFACE PORT commands that identify the ports and are followed by
STACKPORT commands. In the following example, ports 7 and 8 on the master and
provisioned member switches are to be the stack trunk:
interface port1.0.7-1.0.8
stackport
.
interface port2.0.7-2.0.8
stackport
.
interface port3.0.7-3.0.8
stackport
.
interface port4.0.7-4.0.8
stackport
5 Go to “Configuring the x530L-10GHXm Member Switches” on page 185.
Table 24. Verifying the Master x530L-10GHXm Switch (Continued)
Step Description and Command