User Manual – Rev AV AMETEK Programmable Power
MX Series 13
2. Specifications
Specifications shown are valid over an ambient temperature range of 25 r 5q C and apply after a 30
minute warm-up time. Unless otherwise noted, all specifications are per phase for sine wave output
into a resistive load. For three phase configurations or mode of operation, all specifications are for
Line to Neutral (L-N) and phase angle specifications are valid under balanced load conditions only.
Note: Specifications for input and output current and power on MX180, MX225 and MX270
configurations are 4, 5 and 6 times those of MX45-3 and are not separately listed.
2.1 Electrical
2.1.1 Input
(3 phase, 3
(PE))
LL
230 V
LL
r10%
400 V
LL
r10%
480 V
LL
r10%
RMS
187 V
LL
RMS
207 V
LL
60 A
RMS
360 V
LL
50 A
RMS
432 V
LL
RMS
187 V
LL
157 A
RMS
207 V
LL
90 A
RMS
360 V
LL
75 A
RMS
432 V
LL
Each MX30
chassis
requires its
own AC
service.
Total Line
currents are
2 x MX30
c
hassis
requires its
own AC
service.
Total Line
currents are
2 x MX45
Each MX45
chassis
requires its
own AC
service.
Total Line
currents are
Frequency:
85 % (typical) depending on line and load
0.95 (typical) / 0.99 at full power.
pk
LL
220A
pk
@ 230
V
LL
132A
pk
@ 400
V
LL
110A
pk
@ 480
V
LL
Each MX30
chassis
requires its
own AC
service.
Tot
Each MX45
chassis
requires its
own AC
service.
Total Peak
currents are
Each MX45
chassis
requires its
own AC
service.
Total Peak
currents are
Voltage:
2200 VAC input to output
1350 VAC input to chassis