User Manual Rev AV AMETEK Programmable Power
MX Series 95
HARMONICS/TRACE ANALYSIS Screen [3Pi controller only]
The fourth measurement screen is dedicated to the advanced measurements available on the
MX Series with 3Pi controller only. This screen is not available on the P controllers. The
Harmonics/Trace Analysis measurement screen is a true menu screen offering several user
accessible fields. These fields are used to select the desired acquisition trigger and display
mode. The actual data is displayed whenever the ENTER key is pressed while the cursor is on
the VIEW or START field. The following fields are available on this menu:
Figure 4-10: HARMONICS/TRACE ANALYSIS Screen
Entry Description
FUNCTION Selects Voltage, Current or Both parameters for display.
VIEW Available display modes are TABLE, BAR and TRACE.
TABLE mode:
Displays the first 50 harmonics in a
tabular text format.
BAR mode:
Displays the first 50 harmonics in a
graphical bar chart display.
TRACE mode:
Displays the selected Function in a
time domain (waveform) graphical
display.