141ASC70
F8 - 1A
F7 - 15A
F6 - 15A
F5 - 5A
F4 - 1A
F3 - 7,5A
F2 - 10A
F1 - 20A
MAINTENANCE MANUAL
Drain oil after it has cooled down below
50°C (122°F).
Follow the re safety measures!
After disconnecting the hydraulic circuits
blind all holes with plugs.
Collect drained oil; do not leave it soak
into the soil.
Used oil is environmentally dangerous
waste - have them liquidated.
Exchanging the lter element of pressure lter
• Remove the lter. Clean from below the following: contact
surface of the ltration block, spread pure oil over the new
lter’s ring, screw down, tighten.
Filter cartridge
Order number: 4-5358520121
Use original lter elements according to
spare parts catalogue only.
Exchange oil and lter always when ade-
struction of internal parts of the units
occurs (of hydromotors, of hydrogenera-
tors), or during a major overhaul of the
hydraulic system. Clean and rinse out the
hydraulic tank before installing new unit,
and ll it with oil. With the engine running
at increased speed, please test the func-
tions of the Machine. Check the tightness.
Used lter elements are environmentally
dangerous waste - have them liquidated.
! NOTE !
Exchange the lter element always in the following
occasions:
- when changing oil
- if the signal lamp of pressure lter lights up
after the working temperature reached 50
through 60°C (122 - 140°F).