65ASC70
20%
FUEL LEVEL
100
ENG HRS
28°C
COOL TEMP
0 RPM
ENG RPM
100
220
180
250
J1939
°C
°F
80
40
100
120
396061
0
I
II
OPERATION MANUAL
• Turn key in ignition box (1) to position ”l” - the pilot lamps for
brake, recharging, neutral, engine glowing (as per ambient
temperature) will light. ROPS2D indicator lamp will light up
shortly along with acoustic alarm.
• The display will show logo and then 4 quadrants with para-
meters set.
Note
The display has been set by Manufacturer, it is possible to
change it to a single parameter display, refer to par. 2.6.1.
• Glowing indicator lamp goes o, please switch to position
“II” to start the engine and (hold key in ”ll” position only until
engine is started).
Do NOT start for no longer than 30 sec.
Repeat starting only after 2 minutes.
Repeat starting max 3x, then track a fail-
ure within fuel system. Absence of smoke
in exhaust will signal a defect within fuel
supply to the engine.
When started, please check recharging
function - indicator lamp must go o.
Do NOT increase RPM abruptly, let engine
run for 3 to 5 minutes in idle speed so to
stabilize pressure in the engine, and bear-
ings to lubricate. Do not let engine run
idle longer than 10 minutes, engine may
get damaged.
Starting will be interlocked if:
Roller is not braked.
Actuator (2) not in neutral.
STOP button pressed.
Driver not sitting on the seat.