LUME20
Room Pressure Monitor
MANUAL v100
Question and Answer IconNeed help?

Do you have a question about the Antec controls LUME20 and is the answer not in the manual?

Antec controls LUME20 Specifications

General IconGeneral
BrandAntec controls
ModelLUME20
CategoryMonitor
LanguageEnglish

Summary

INTRODUCTION

General

Overview of information covered in the manual, including technical specifications and installation procedures.

Product Overview

Description of LUME20's purpose and its key features for monitoring room pressure.

General Installation Information

Guidelines and precautions for installing the LUME20 device safely and correctly according to standards.

Technical Specifications

GETTING STARTED WITH LUME20

In the Box

Lists the components included with the LUME20 unit and optional accessories available for purchase.

LUME ACCESSORIES

Differential Pressure Sensor (SDPT)

Details the SDPT sensor used for pressure measurement, including its model, features, and specifications.

Door Contact Switch (DCS)

Explains the function and connection of Door Contact Switches for detecting door open/closed status.

MECHANICAL INSTALLATION

Installation and Mounting Instructions

Provides step-by-step instructions for mounting the LUME20 on drywall, EU wall box, or single-gang electrical box.

Pressure Sensor Installation Instructions

Selecting a Location for Installation

Guides on choosing optimal locations for pressure sensor plates and the SDPT for accurate pressure readings.

Mounting Sensor Plates

Details the steps for mounting sensor plates and connecting pressure tubing to the SDPT.

ELECTRICAL INSTALLATION

Sample Wiring Diagram

Illustrates the typical wiring connections for the LUME20, including power, sensors, and outputs.

BACnet MS/TP Network

What is BACnet?

Explains BACnet MS/TP as a communication protocol for LUME20 to building automation networks.

Network Addressing

Details how to assign unique MAC addresses and Device Instances for LUME20 on a BACnet network.

Physical Connection

Describes the three-wire BACnet network architecture, daisy-chaining, and segment limitations.

DISPLAY NAVIGATION

Initial Setup

Guides users through the initial setup wizard for configuring the LUME20 device upon first power-on.

Home Screen

Normal Operation

Describes the display components and information shown on the LUME20 home screen during normal operation.

Screen Saver

Caution Active

Display Component Descriptions

Details the display elements for Caution Active status, including Room Name, Status, Reason, and Mode.

Alarm Active

Display Component Descriptions

Details the display elements for Alarm Active status, including Room Name, Status, Reason, and Mode.

Alarm Silence

SETTINGS

Mode Override

Allows the user to manually override the current room mode through the device interface.

Room Modes

Room Mode & Override Priority

Explains the priority of different room modes and how they are triggered by inputs or overrides.

Adding a Room Mode

Describes the process of adding new room modes to the LUME20 configuration.

Removing a Room Mode

Room Mode - Settings

Mode Options

Details the configurable options for each room mode, including name, color, and sidebar behavior.

Monitored Rooms

Adding a Monitored Room

Guides on adding new rooms to be monitored by the LUME20 device.

Removing a Monitored Room

Monitored Room - Settings

Room Settings

Configures room-specific parameters like name, pressure mode, alarms, and cautions.

Inputs

Input Configuration

Details how to configure Universal Inputs as Analog, Thermistor, or Binary inputs for various sensor types.

Analog Input – Room Pressure

Pressure Settings

Configures voltage and pressure ranges, scaling, and averaging for room pressure sensor inputs.

Analog Input - Temperature

Temperature Settings

Configures voltage and temperature ranges for temperature sensor inputs.

Analog Input - Relative Humidity

Humidity Settings

Configures voltage and humidity ranges for relative humidity sensor inputs.

Analog Input - Gas Concentration

Gas Concentration Settings

Configures voltage and gas concentration ranges for sensor inputs.

Analog Input - ACH

ACH Settings

Configures voltage and ACH ranges for Air Changes per Hour sensor inputs.

Thermistor - Temperature

Thermistor Settings

Configures offset and reads temperature and resistance from thermistor sensors.

Binary Input - Door

Door Input Settings

Configures binary inputs for door status, including alarm and caution during delay settings.

Binary Input - Mode Switch

Mode Switch Settings

Configures binary inputs to switch between different room modes.

Binary Input - Trigger Alarm or Trigger Caution

Alarm/Caution Trigger Settings

Configures binary inputs to trigger alarms or cautions, setting alert messages.

Outputs

Analog Output – Room Pressure

Configures an analog output for the room pressure reading, used for external monitoring or control.

Binary Output – Alarm/Caution

Alarm/Caution Output Settings

Configures binary outputs to activate based on specific alarm or caution types.

Binary Output – Normal

Normal Output Settings

Configures binary outputs to activate when no alarms or cautions are active.

Binary Output – Door Status

Door Status Output Settings

Configures binary outputs to indicate when a door is open.

Binary Output – Room Mode

Room Mode Output Settings

Configures binary outputs to activate based on the selected room mode.

Binary Output – Binary Input

Binary Input Output Settings

Configures binary outputs to follow the state of a selected binary input.

BACnet

BACnet Configuration

Configures BACnet communication settings like device name, MAC address, and baud rate.

BACnet Polling Points

Adding a BACnet Polling Point

Guides on adding BACnet points to be polled by LUME20 for display on the home screen.

Removing a BACnet Polling Point

BACnet Polling Point – Settings

Polling Point Configuration

Configures settings for BACnet polling points, including display name, units, and polling delay.

Single Room Monitoring – Multipage Home Page Type

Single Room Monitoring – Single Page Home Page Type

Triple Room Monitoring

User Preferences

Preference Settings

Allows customization of units, alarm sounds, screen dimming, brightness, and password settings.

LUME ASSISTANT

System Requirements

Lists the minimum hardware and software requirements to run the LUME Assistant software.

Installation Requirements

Provides instructions for installing LUME Assistant, including Windows Defender firewall configuration.

How to Connect to LUME20

Tools Required

Lists the necessary tools and hardware for connecting to the LUME20 device via Ethernet.

LUME Assistant Start-Up

Guides on starting the LUME Assistant software, including update checks and firmware management.

Home (LUME Assistant)

Configuration

Manages configuration files for the LUME device, allowing retrieval and upload of settings.

Commissioning Report

Generates a commissioning report from device configuration or a selected file.

Firmware Update

Updates the firmware of the connected LUME device to the latest available version.

Diagnostics (LUME Assistant)

Retrieve Diagnostics Files

Retrieves diagnostic files from the connected LUME and LUME Assistant onto the computer.

Remove Configuration Files

Deletes configuration files from the LUME device, prompting a reboot into setup.

Remove BACnet Overrides

Removes any BACnet override files from the connected LUME device.

Restart LUME

Restarts all connected LUME pressure monitors.

Help (LUME Assistant)

View Changelog

Displays a changelog of LUME Assistant versions and their respective changes.

Adjusting Windows Defender™ Firewall Settings

Firewall Configuration Steps

Provides step-by-step instructions to allow LUME Assistant through the Windows Defender Firewall, including locating the program and configuring exceptions.

MAINTENANCE

Replacement Parts

Information on how to obtain replacement parts for the LUME20 device.

Technical Support

Contact information for technical support via email and phone, including hours of operation.

APPENDIX A

Lume™™ Drywall Cut-Out

Provides a template and dimensions for cutting a drywall opening for LUME mounting.