Language | English |
Overview of information covered in the manual, including technical specifications and installation procedures.
Description of LUME20's purpose and its key features for monitoring room pressure.
Guidelines and precautions for installing the LUME20 device safely and correctly according to standards.
Lists the components included with the LUME20 unit and optional accessories available for purchase.
Details the SDPT sensor used for pressure measurement, including its model, features, and specifications.
Explains the function and connection of Door Contact Switches for detecting door open/closed status.
Provides step-by-step instructions for mounting the LUME20 on drywall, EU wall box, or single-gang electrical box.
Guides on choosing optimal locations for pressure sensor plates and the SDPT for accurate pressure readings.
Details the steps for mounting sensor plates and connecting pressure tubing to the SDPT.
Illustrates the typical wiring connections for the LUME20, including power, sensors, and outputs.
Explains BACnet MS/TP as a communication protocol for LUME20 to building automation networks.
Details how to assign unique MAC addresses and Device Instances for LUME20 on a BACnet network.
Describes the three-wire BACnet network architecture, daisy-chaining, and segment limitations.
Guides users through the initial setup wizard for configuring the LUME20 device upon first power-on.
Describes the display components and information shown on the LUME20 home screen during normal operation.
Details the display elements for Caution Active status, including Room Name, Status, Reason, and Mode.
Details the display elements for Alarm Active status, including Room Name, Status, Reason, and Mode.
Allows the user to manually override the current room mode through the device interface.
Explains the priority of different room modes and how they are triggered by inputs or overrides.
Describes the process of adding new room modes to the LUME20 configuration.
Details the configurable options for each room mode, including name, color, and sidebar behavior.
Guides on adding new rooms to be monitored by the LUME20 device.
Configures room-specific parameters like name, pressure mode, alarms, and cautions.
Details how to configure Universal Inputs as Analog, Thermistor, or Binary inputs for various sensor types.
Configures voltage and pressure ranges, scaling, and averaging for room pressure sensor inputs.
Configures voltage and temperature ranges for temperature sensor inputs.
Configures voltage and humidity ranges for relative humidity sensor inputs.
Configures voltage and gas concentration ranges for sensor inputs.
Configures voltage and ACH ranges for Air Changes per Hour sensor inputs.
Configures offset and reads temperature and resistance from thermistor sensors.
Configures binary inputs for door status, including alarm and caution during delay settings.
Configures binary inputs to switch between different room modes.
Configures binary inputs to trigger alarms or cautions, setting alert messages.
Configures an analog output for the room pressure reading, used for external monitoring or control.
Configures binary outputs to activate based on specific alarm or caution types.
Configures binary outputs to activate when no alarms or cautions are active.
Configures binary outputs to indicate when a door is open.
Configures binary outputs to activate based on the selected room mode.
Configures binary outputs to follow the state of a selected binary input.
Configures BACnet communication settings like device name, MAC address, and baud rate.
Guides on adding BACnet points to be polled by LUME20 for display on the home screen.
Configures settings for BACnet polling points, including display name, units, and polling delay.
Allows customization of units, alarm sounds, screen dimming, brightness, and password settings.
Lists the minimum hardware and software requirements to run the LUME Assistant software.
Provides instructions for installing LUME Assistant, including Windows Defender firewall configuration.
Lists the necessary tools and hardware for connecting to the LUME20 device via Ethernet.
Guides on starting the LUME Assistant software, including update checks and firmware management.
Manages configuration files for the LUME device, allowing retrieval and upload of settings.
Generates a commissioning report from device configuration or a selected file.
Updates the firmware of the connected LUME device to the latest available version.
Retrieves diagnostic files from the connected LUME and LUME Assistant onto the computer.
Deletes configuration files from the LUME device, prompting a reboot into setup.
Removes any BACnet override files from the connected LUME device.
Restarts all connected LUME pressure monitors.
Displays a changelog of LUME Assistant versions and their respective changes.
Provides step-by-step instructions to allow LUME Assistant through the Windows Defender Firewall, including locating the program and configuring exceptions.
Information on how to obtain replacement parts for the LUME20 device.
Contact information for technical support via email and phone, including hours of operation.
Provides a template and dimensions for cutting a drywall opening for LUME mounting.