Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
REV.
B
Page 31 of 95
10. The P.O.M. Lock is manufactured to install in frame on top of handle rail side of door.
11. For retrofitting the P.O.M. Lock on existing doors in the field, contact Anthony
Customer Service or the local Sales Representative for information and instructions.
33. P.O.M. Lock Installation
1. To install the retrofit retainer, measure in 1-1/2” from the edge of door (handle side) and
mark frame above the door.
2. Place template provided on frame, with the right edge of the template on the mark
previously made on the frame.
3. Mark the frame through the five (5) holes on the template with a pencil. Remove
template and center punch the marks on the frame.
4. Drill the four (4) outboard holes with an 11/64drill, the center hole with a 5/8” drill and
deburr holes.
5. Place retrofit retainer bracket over the holes with the rectangular notch out. Use #10-32
x 5/16” screws provided and mount retainer bracket to frame.