Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
39. Humastat Installation Procedure
1. Install Humastat Power Junction Box before refrigerator door power wiring, on the inside
wall of refrigerator.
2. Remove wiring compartment covers by removing four (4) sheet metal screws.
3. Connect heater hot wire to Red wire from control unit.
4. Connect input power hot wire to Black wire from control unit.
5. Connect all White wires, including common side of power line, line load and control unit
White wire.
6. Connect Green Ground wire from control unit to Green Ground wire at frame and to
incoming Ground wire (if furnished).
7. Replace the Wiring Compartment Cover with the sheet metal removed in No. 2 above.