Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
REV.
B
Page 56 of 95
62. Normal Temp & Low Temp 120-Volt Ballast and Lamp Wiring Diagram -
Pre-Wired 1-Light System
Wiring:
1. Ballast has two (2) Red wires, two (2) Blue wires, a Black and a White wire.
a. Wire two (2) Red wires to two (2) Red wires on bottom socket.
b. Wire two (2) Blue wires to two (2) Blue wires on top socket.
c. Black wire goes to hot, White wire goes to neutral.
63. Ballast Replacement
1. For replacement ballast, always use ballast number from existing ballast.
2. Remove door from frame opening.