Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
STYLE: Normal temp doors with heaters, 3-Pane Non-Heated Glass or 2-Pane Reflective NHG
APPLICATION: Case Temperature 33°
F, Humidity 68% or less, @ 75
F ambient.
STYLE: Normal temp doors with heaters, 2-Pane Heated Glass
APPLICATION: Case Temperature 31°
F, Humidity 80% or less, @ 75
F ambient.
NOTES: 1. All amperages are design amperages subject to the following tolerances: non-heated glass +/- 5%,
heated glass +/- 8%.
2. Although the amperages are calculated at 120 volts, all doors are designed to operate without
sweating when used within the application parameters with a voltage range of +/- 10%.
3. Design parameters do not make allowances for factors such as air leaks or unusual air flow
patterns within cases; therefore, some sweating may occur when upper limits of temperature or
humidity are encountered.