9. Maintenance
9.1. Conguraon File Handling
9.1.1. Export Conguraon
You can export the current conguraon, in order to import and use the same sengs to congure addional
Communicator.
Figure 38. Files & rmware page
To export a conguraon le:
In Files & rmware, click Export.
The conguraon sengs are stored in a .conf le and downloaded to your PC.
Maintenance Anybus
®
Communicator
- PROFINET IO-Device to EtherNet/IP Adapter
SCM-1202-195 Version 1.0 Page 43 of 56

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anybus Communicator and is the answer not in the manual?

Anybus Communicator Specifications

General IconGeneral
Protocols SupportedPROFINET, EtherNet/IP, Modbus TCP
Serial InterfacesRS-232, RS-485
Ethernet ProtocolsModbus TCP, EtherNet/IP, PROFINET
CAN ProtocolsCANopen
Operating Temperature-25°C to +70°C
Storage Temperature-40°C to +85°C
Humidity5% to 95% non-condensing
Power Supply24V DC
EnclosurePlastic
Protection ClassIP20