Command Details: File Write
Category
Extended
Details
Command Code: 16h
Valid for: Instance
Description
Writes data to a file previously opened for writing or appending.
Command Details
Response Details
Command Details: Directory Open
Category
Extended
Details
Command Code: 20h
Valid for: Instance
Description
This command opens a directory.
Command Details
Response Details
(no data)
Field Contents Comments
CmdExt[0] (reserved, set to zero) -
CmdExt[1]
Data[0... n] Data Data to write to file
Field Contents Comments
CmdExt[0] Bytes no. of bytes written
CmdExt[1] (reserved, ignore) -
Field Contents Comments
CmdExt[0] (reserved, set to zero) -
CmdExt[1]
Data[0... n] Path + name of directory Relative to current path