156
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.4
10.2 Functional Safety Host Object (E8h)
Category
Extended
Object Description
Important: Do not implement this object if a safety module is not used.
This object specifies the safety settings of the application. It is mandatory if Functional Safety is to be
supported and a safety module is connected to the Anybus CompactCom module.
Supported Commands
Object: Get_Attribute
Instance: Get_Attribute
Object Attributes (Instance #0)
# Name Access Data Type Value
1 Name Get Array of CHAR Functional Safety’
2 Revision Get UINT8 01h
3 Number of instances Get UINT16 0001h
4 Highest instance no. Get UINT16 0001h

Table of Contents