EasyManua.ls Logo

Anybus CompactCom 40 EtherNet/IP - Page 73

Anybus CompactCom 40 EtherNet/IP
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CIP Objects 73
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
Class 3 Connection Details
Explicit message connection
Class 3 connections are used to establish connections towards the message router. Thereafter,
the connection is used for explicit messaging. Class 3 connections use TCP transport.
- No. of simultaneous Class 3 connections: 6
- Supported RPI: 100 - 10000 ms
- T->O Connection type: Point-to-point
- O->T Connection type: Point-to-point
- Supported trigger type: Application
- Supported connection size: 1448 bytes
- Supported priorities: Low

Table of Contents

Related product manuals