TD 92639EN
08 December 2012 / Ver. H
Configuration Manual
Ascom d62 DECT Handset
32
Location Information during Call
When the Admin menu is activated and DECT location is enabled, the DECT locat
ion
information screen can be accessed during a call by pressing the soft key "More" and select
"Location info".
5.21 Special Location
It is possible to configure a handset to automatically send its location to the system each
time it receives a valid location from a Location Device having the parameter “Immediate
Alarm Transmission” enabled.
Note: A handset that receives a new locat
ion already visited within the last 3 seconds will
not send the location towards the system. This will prevent unwanted repetitions of special
locations in the system
In a template or Number in PDM/Devi
ce Manager, the parameter for activation is found at:
Location > Special location
5.22 Poll Location
A system/application can request a location of a handset. When location of the handset is
requested, the handset send its exactly location (DECT location enabled), or an approximate
location (Base Station positioning enabled) depending on the set parameters in the
handset.
If DECT location is enabled, the handset sends the four l
ast received DECT location IDs
together with the time since they were received. See also 5.20 DECT Location on
page 30.
If Base Station positioning is enabled, the handset sends the best-rated Base Station ID
togethe
r with the time since it was received. See also 5.19 Base Station Positioning on
page
29.
5.23 Site Survey Tool
See User Guide, Site Survey Tool, TD 92220GB.
5.24 Common Alarm Settings
Note: This feature is applicable for d62 Protector only.
In a template or Number in PDM/Devi
ce Manager, the parameters for activation are found
at:
Alarm > Common
Parameters in the current version are:
Stored alarm data
Information that shall be sent along an alarm (for example a handset´s location)
Indicate triggered alarm with LED
1
Indicate triggered alarm with vibrator
1
Indicate triggered alarm with beeper signal
1
1. If the parameter "Silent alarm" is set, no indication will be shown when an alarm has been sent or received.