Handset Configuration
CONFIGURATION MANUAL
Ascom d83 DECT Handset
Information about the handset location can also be sent along with an alarm, see 5.19 Base Station
Positioning, page 27, 5.20 BLE Location, page 28, 5.21 DECT Location, page 30, 5.22 IR Location, page 32
and 5.23 LF Location, page 35.
5.29 Pull-Cord Alarm
The handset can be configured to send an alarm when the pull-cord is pulled off the handset.
In a template or Number in PDM/Device Manager, the parameters for activation are found at:
Alarm Pull-cord alarm
The alarm can also be activated in the handset, refer to the User Manual, Ascom d83 DECT Handset,
TD 93434EN.
Parameters in the current version are:
Pull-cord alarm
Warning sound when detached
ALS
Mode for automatic call after alarm
See also 5.27 Common Alarm Settings, page 37 for additional parameter settings.
Information about the handset location can also be sent along with an alarm, see 5.20 BLE Location, page
28, 5.21 DECT Location, page 30, 5.22 IR Location, page 32 and 5.23 LF Location, page 35.
5.30 Man-Down Alarm and No-Movement Alarm
Man-down alarm: If the handset is tilted 45 degrees1 (default) or more for a preset time (default 7 seconds),
the Man-down alarm is triggered.
No-movement alarm: If no movement is detected during a preset time (default 30 seconds), the No-
movement alarm is triggered.
The parameters for activation are found at:
Alarm Man-down and No-movement alarm
The alarms can also be activated in the handset, refer to the User Manual, Ascom d83 DECT Handset,
TD 93434EN.
Parameters in the current version are:
Man-down alarm
Determines if the Man-down alarm is enabled or disabled.
Man-down detection time
Determines when the warning phase starts after man-down is triggered.
Man-down warning angle
Determines the angle the handset must be tilted to trigger the Man-down alarm.
Reset man-down warning automatically
Determines if the Man-down warning is reset when putting the phone in a vertical position.
No-movement alarm
Determines if the No-movement alarm is enabled or disabled.
40
TD 93426EN / 28 January 2022 / Ver. C

Table of Contents

Other manuals for ASCOM d83

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASCOM d83 and is the answer not in the manual?

ASCOM d83 Specifications

General IconGeneral
BrandAscom
Modeld83
Caller IDYes
SpeakerphoneYes
Answering MachineNo
Battery LifeUp to 200 hours standby
Number of Handsets1
RangeUp to 300 meters outdoors

Related product manuals