TD 92599EN
1 September 2011/ Ver. B
User Manual
Ascom i62 VoWiFi Handset
39
7.2 Man-down and No-movement Alarm
Note: Applicable to Protector only. The handset version must be WH1-AAAA/2A or above
(see label under battery cover). These functions require a license.
The Man-down alarm will react if the VoWiFi Handset is tilted (default 45°) from the vertical
for a predefined period of time (default 7 seconds). The No-movement alarm will react if no
movement is detected during a predefined period of time (default 30 seconds).
The VoWiFi Handset alerts by beep, vibrator and LED signals, depending on the settings,
during a predefined period of time (default 7 seconds). At the same time the VoWiFi
Handset displays the message “Man-down warning. Cancel?“ or “No-movement warning.
Cancel?“.
The VoWiFi Handset then sends the alarm, unless the alarm is cancelled. The VoWiFi Handset
will confirm that the alarm has been sent by beep, vibrator and LED signals. In addition the
VoWiFi Handset displays the message “Man-down warning sent“ or “No-movement
warning sent“.
The VoWiFi Handset location is sent along with the alarm, see 7.5 Alarm with Additional
Information on page 40.
If configured in the Device Manager, an Acoustic Location Signal (ALS) is activated after the
alarm has been sent, see 7.3 Acoustic Location Signal on page 40.
The VoWiFi Handset may be programmed to automatically call a predefined telephone
number after the alarm has been sent, see 7.4 Automatic Call after Alarm on page 40.
The Man-down and No-movement alarm functions are inactive under the following
conditions:
• While the VoWiFi Handset is placed in a charger.
• During calls (depending on settings), to avoid false alarms if the user tilts the VoWiFi
Handset or is motionless during a call.
• For a predefined period of time (default 10 minutes) if the Mute button is pressed
during the alert signal.
Activate/Deactivate the Man-down and/or No-movement Alarm
Enter “Settings” , and step to “Alarm”.
Then select the wanted alarm(s) and press Back repeatedly.
The corresponding icon(s) appear on the display.
Follow the same steps to deactivate the alarm(s).
Cancel Man-down and No-movement Alarm
Press the soft key “OK“ to confirm “Man-down warning. Cancel?“ or “No-movement
warning. Cancel?“ which appears in the display during the alert signal or press any key.
Delay Man-down and No-movement Alarm Temporarily
Press the Mute button during the alert signal and then press “Yes“ to confirm the
message “Delay MD/NM detection?“.
The corresponding display icon will keep flashing until the alarm is active again (default 10
minutes).