Chapter 5 - Accessories
UM-18400E-U ATEQ F580 User manual Page 146/168
2.3. OPTIONAL REMOTE INPUT / OUTPUT MODULE
2.3.1. Appearance of the module
For remote management of the external heads, if there are long distances between the
measurement cells and the central unit, there is an accessory, an input/output module.
If this is used, cables between the various elements can be limited. In effect the
connecting cable simply becomes the network connecting cable.
A remote input/output module can manage a maximum of three measurement heads.
The case looks like this :
Front panel:
16 15 14 13 12 11 10 C 8 7 6 5 4 3 2 C
C 2 3 4 5 6 7 8 C 10 11 12 13 14 15 16
24 V
RUN
DIAL/COM
CNOMO
CE
REF. 188.00 N.
www.ateq.com
MADE BY ATEQ
J1
J5
SORTIES/OUT
ENTREES/IN
RS485
ENTREES/IN
J3 J4
RS485
SORTIES/OUT
ECHELON
J1
60 V
≈
/== max.
500mA max.
24V ==
3m