127127
EN
Warnings
Installation
Use
Water heater 270 litres 200 litres 150 litres
Water setpoint temperature setting
range
°C 50 - 55 50 - 55 50 - 55
Heat pump operating temperature
range
°C
-15 - 37 -15 - 37 -15 - 37
Initial refrigerant charge kg 0.700 0.700 0.700
CO2 equivalent tCO2eq 0.47 0.47 0.47
Refrigerant charge to volume of
water
kg/l 0.0026 0.0035 0.0047
GWP of the gas used - 675 675 675
Certied output at 7° C ambient temperature (CDC LCIE 103-15/D)
Coecient of performance (COP)* -
3.37 3.07 3.09
Power consumption at stabilised
speed (Pes)*
W
24 18 17
Heating time (tr)* h.mins
03.46 02.59 02.22
Reference temperature (Tref)* °C
53.6 52.9 54.1
Drawing o prole - XL l l
Max. amount of mixed water at 40°
C (V40)*
l 339.6 268.9 202.2
V40td (8 h HC) l 416.6 303.3 234.7
Energy eciency (nwh)* % 138 126 127
* Performance measured in ex-factory ECO manual mode at 10°C to 55°C for the 150
L and 10°C to 54°C for the 200 L and the 270 L at atmospheric pressure in accordance
with the NF Electric Output functional specications of LCIE No. 103-15/D for standalone
thermodynamic water heaters (based on standard EN 16147).
**Tested in an echo chamber in accordance with the protocol dened by standard
EN12102-2.